SUJA GLOBAL Data Logging Sound Level Meter (SM-841)
৳ 45,000.00
- Accuracy ±1.4dB.
- Frequency range 31.5Hz~8kHz.
- Dynamic range 50dB.
- Measuring level range 30dB~130dB.
SUJA GLOBAL Data Logging Sound Level Meter (SM-841)
৳ 45,000.00Request a Call Back
- Size Guide
Size Guide
Size Chest Waist Hips XS 34 28 34 S 36 30 36 M 38 32 38 L 40 34 40 XL 42 36 42 2XL 44 38 44 All measurements are in INCHES
and may vary a half inch in either direction.
Size Chest Waist Hips 2XS 32 26 32 XS 34 28 34 S 36 30 36 M 38 32 38 L 40 34 40 XL 42 36 42 All measurements are in INCHES
and may vary a half inch in either direction.
Size Chest Waist Hips XS 34 28 34 S 36 30 36 M 38 32 38 L 40 34 40 XL 42 36 42 2XL 44 38 44 All measurements are in INCHES
and may vary a half inch in either direction.
- Delivery & Return
Delivery
We ship to all 50 states, Washington DC.
All orders are shipped with a UPS tracking number.
Always free shipping for orders over US $200.
During sale periods and promotions the delivery time may be longer than normal.
Return
Elessi will accept exchanges and returns of unworn and unwashed garments within 30 days of the date of purchase (14 days during the sales period), on presentation of the original till receipt at any store where the corresponding collection is available within the country of purchase.
Your return will usually be processed within a week to a week and a half. We’ll send you a Return Notification email to notify you once the return has been completed.
Please allow 1-3 business days for refunds to be received to the original form of payment once the return has been processed.Help
Give us a shout if you have any other questions and/or concerns.
Email: [email protected]
Phone: +1 (23) 456 789 - Ask a Question
SUJA GLOBAL Data Logging Sound Level Meter (SM-841)
৳ 45,000.00Ask a Question
This best USB Data Logging Sound Level Meter. SUJA GLOBAL Data Logging Sound Level Meter (SM-841) is a handheld, professional & portable decibel (dB) meter. So that Data Logging Sound Level Meter is built-in data logging system and can record real-time noise as well.
The SUJA GLOBAL Data Logging Sound Level Meter (SM-841) 30 to 130dB allow to record and monitor sound or noise in 2 class of noise which is dBA [A frequency weighting (the noise that human car can hear)] and dBC [C frequency weighting (response to machine monitor)]. It’s a hand-held device also tripod mounted. Recorded data is monitorable on a Computer or PC by using the delegated software.
It is USB Data Logging Sound Level Meter is designed to meet the measurement requirements of safety engineers, health, industrial safety offices, and sound quality controlling various environments like construction, factories, schools, offices, traffic access, household, stereos, etc.
FEATURES OF SUJA GLOBAL DATA LOGGING SOUND LEVEL METER (SM-841)
- Accuracy ±1.4dB.
- Frequency range 31.5Hz~8kHz.
- Dynamic range 50dB.
- Measuring level range 30dB~130dB.
- Frequency weighting A & C.
- Time weighting FAST 125ms;SLOW ( 1s ).
- Microphone 1/2 inch electrets condenser microphone.
- Data recording PC real-time monitoring and recording.
- Auto power off Meter automatically shuts down after approx. 15 minutes inactivity.
- Power supply One 9V battery, 006P or IEC 6F22 or NEDA 1604.
- Battery life at least 30 hours.
- Operating conditions -20℃~60℃; 10%RH~90%RH.
- Storage conditions -20℃~60℃; 10%RH~75%RH.
SPECIFICATION OF SUJA GLOBAL DATA LOGGING SOUND LEVEL METER (SM-841)
Name | Details |
---|---|
Model | SM-841 |
Brand | SUJA GLOBAL |
Origin | Singapore |
Accuracy | ±1.4dB |
Frequency range | 31.5Hz~8kHz |
Dynamic range | 50dB |
Measuring level range | Auto:30dB~130dB |
Lo:30dB~80dB | |
Med:50dB~100dB | |
Hi: 80dB~130dB | |
Frequency weighting | A & C |
Time weighting | FAST 125ms;SLOW ( 1s ) |
Microphone | 1/2 inch electrets condenser microphone |
Max Hold | MAX |
Min Hold | MIN |
HOLD | Hold the readings |
Alarm function | “OVER” is when input is more than upper limit of range. |
“UNDER” is when input is less than lower limit of range. | |
Analog output | AC/DC outputs from earphone outlet AC=1Vrms ,DC=10mV/dB |
Data recording | PC real-time monitoring and recording. |
Auto power off | Meter automatically shuts down after approx. 15 minutes inactivity. |
Power supply | One 9V battery, 006P or IEC 6F22 or NEDA 1604. |
Battery life | at least 30 hours |
Operating conditions | -20℃~60℃; 10%RH~90%RH |
Storage conditions | -20℃~60℃; 10%RH~75%RH |
Dimension (L*W*H) | 252*66 *33 mm |
Weight | 262g |
VIDEO REVIEW OF SUJA GLOBAL DATA LOGGING SOUND LEVEL METER (SM-841)
Based on 0 reviews
|
|
0% |
|
|
0% |
|
|
0% |
|
|
0% |
|
|
0% |
- Agricultural Machinery
- All Kinds of Meter
- AC & DC Testing Meter
- Anemometer
- Aqua Boy Moisture Meter
- Chlorophyll Meter
- Coating Thickness Gauge
- DO Meter
- Environment Meter
- Flow Meter
- GAS Detectors
- Grain Moisture Meter
- Infrared Thermometer
- IR thermometer
- Laser Distance Meter
- Lutron Meters
- Lux Meter
- Measuring Instrument
- Moisture Meter
- Oxygen Flow Meter
- Paper Moisture Meter
- PH Meter
- Pulse Oximeter
- Sound Level Meter
- Spectrophotometer
- Tachometer
- TDS Meter
- Temperature Hygrometer
- Vibration Meter
- Water Testing Meter
- Construction Equipment
- Digital Scale and Balance
- Garments Machinery
- Home Appliances
- Lifting Equipment
- Safety Equipments
- Textile Lab Consumables
- Textile Lab Machinery
- Button Snap Pull Tester
- Color Matching Cabinet
- Crockmeter Machine
- Digital Pipette Machine
- Fixed Angle Table
- Fusing Bond Tester
- GSM Cutter & Balance
- Hardness Tester
- Laboratory Drying Oven
- Laboratory Incubator
- Laboratory Shaker
- Light Box Cabinet
- Magnetic Stirrer
- Munsell Hue Test Kit
- Perspiration Tester
- Sharp Point Tester
- Shrinkage Template
- Spray Rating Tester
- Swatch Cutter
- Tearing Tester
- Textile Moisture Meter
- Thickness Tester
- Twist Tester Machine
- Washing Machine
- Wrap Reel Machine
- Washer and Dryer
- best calibration weight supplier bd
- Best Light Box Cabinet Price in Bangladesh
- Buy Light Box Cabinet BD
- calibration weight bd
- Color Light Box BD
- Cost of Light Box Cabinet BD
- Emergency Eyewash Station BD
- eye wash
- EYE WASH BD
- Eye Wash Price in Bangladesh
- Eye Wash Station
- Eye Wash Station Price in Bangladesh
- EYE WASH SUPPLIER IN BD
- fabric gsm cutter bangladesh
- fabric gsm cutter machine bd
- GSM Cutter
- GSM Cutter BD
- GSM Cutter Machine Bangladesh
- GSM Cutter Machine Price BD
- GSM Cutter Machine Price in Bangladesh
- GSM Cutter Price BD
- gsm cutter price in bangladesh
- gsm cutter size bd
- GSM Fabric Cutter BD
- gsm paper cutter bd
- GSM Round Cutter BD
- GSM Sample Cutter BD
- gsm square cutter bd
- gsm square cutter price in bangladesh
- iron table
- Light Box Cabinet
- Light Box Cabinet Cheap Price BD
- Light Box Cabinet for Artwork BD
- Light Box Cabinet for Clothes BD
- Light Box Cabinet for Design BD
- Paper GSM Cutter BD
- paramount gsm cutter machine
- sagartexbd
- seller
- standard calibration weight
- standard calibration weight bd
- steam generator
- suja global
- weight set
- weight set bd
Related Products
- Combustible Gas : 0~100% LEL.
- Operating temperature -10~50℃.
- Operating humidity 15%-95%RH (Standard).
- Measuring range O²: 0~30% VOL CO : 0~999 PPM H²S : 0~500 PPM.
- LCD Display 3.5 digits display.
- Operating Condition 0C ~40C.
- Measuring Accuracy 5%Hz 2digits.
- Accelerated Measuring Range 0.1~199.9m/s2 (Peak value)
- Accuracy ± 0.5%n.
- Resolution 0.1.
- Temperature 0-60°C.
- Measuring Range 0-80%.
- Display 20 x 28mm.
- Measurement range 0 to 14 pH x 0.01pH.
- Resolution 0.01 pH.
- Accuracy ± 0.07 pH (pH 5 to pH9).
15 in stock
- Display LCD, resolution 0.1.
- Accuracy ±1 % full scale.
- Reproducibility ±0,3 %.
- Auto Power off After 2 min of non-use.
- pH Accuracy ±0.01+1LSD.
- mV Accuracy ±2 mV.
- Temperature Range -10.0°C~110.0°C.
- Temperature Resolution 0.1°C.
12 in stock
- Sensitivity Variable, minimum 5ppm (gasoline).
- Operation Time 9 hours (slightly vary with working condition).
- Leak Size Indication Indication Light & Alarm Buzzer.
- Operation Condition 0°C~ 50°C ; ≤80%RH (Non Gel).
15 in stock
- Measuring Range 1~100.000lux.
- Accuracy ±4%rdg ±10 digits.
- Repeatability ±2%.
- Operation Condition 0 °C ~ 40°C.
- Accuracy ±5%or ±10PPM.
- Response time < 1 sec.
- Operating Temperature 0~50°c.
- Measurement Range 0~1000PPM.
9 in stock
- TResolution 0.1%.
- Measuring range 0~30% VOL.
- Operating temperature -10~50℃ .
- Operating humidity 15%-95%RH (Standard).
- Wind Speed Measuring Range 0~45m/s.
- Wind Speed Accuracy Accuracy ±3% ±0.1 digit.
- Wind Speed Units m/s,Ft/min,Knots,km/h,Mph.
- Wind Speed Resolution 0.1m/s.
10 in stock
- Accuracy ±0.5%.
- Measurement range 10% to 85%.
- Measurement error in the range 70 ~ 78% ≤ 1.0%.
- Display 3 LCD (with back light).
24 in stock
Reviews
There are no reviews yet.